DTS(X)F1353/DSS(X)F1353 Three phase multi-rate active&reactive energy meter
|
【Order Info】
|
| Description: |
Summary
DTS(X)F1353/DSS(X)F1353 Three phase static multi-rate Active & Reactive energy meter is designed by using advanced special measuring chip, modern multi-tariff technology, digital sampling technology and SMT manufacturing technique.
DTS(X)F1353/DSS(X)F1353 Three phase static multi-rate Active & Reactive energy meter conforms to CEI IEC62052-11-2003 Electricity metering equipment(a.c.)General requirements, tests and test conditions part 11: metering equipment; CEI IEC 62053-21-2003 Electricity metering equipment (a.c.)particular requirements part 21: static meters for active energy (class 1 and 2)equipment, CEI IEC 62053-23 Electricity metering equipment (a.c.)particular requirements part 23: static meters for reactive energy (class 2 and 3)equipment, GB/T15248-2002 Special requirements on multi-rate energy meter and DL/T645-1997 multi-function communication protocol.
Functions and features
- Positive and negative active energy measuring (negative energy can be counted into positive energy)in TOU, Positive and negative reactive energy measuring(negative energy can be counted into positive energy)in TOU, Max demand under different tariff and the total with occurring time. Sliding time can be set as required. Real-time power can be displayed.
- Energy measurement in Tou: 2 time zones,4 tariffs, 10 time segments and 2 day tables
- Real-time measurement of voltage, current etc
- Meter reading and programming via infrared and RS485 port with program lock and authorized password.
- Data storing auto or manually (data storing time can be set at any time in a day within 1st-28th day in a month),history data of active energy can be recorded.
- Impulse output, RTC test output
- Waking up by button, broadcast time synchronization, program prohibited, meter reset
- Real-time detection on meter parts and program running status with alarm function
- Insulated RS485 port and lightning proof circuit inside the meter
- LCD display(backlight is optional)
- Last 10 voltage missing records including voltage-missing phase, start and stop time, total voltage-missing energy etc; 9 times of power on/off records
|
Items |
Technical Parameters |
|
Rated voltage |
3*220/380V(Three phase 4 wire);3*100V(Three phase 3 wire) |
|
Basic current |
1.5(6)A、5(20)A、10(40)A、15(60)A、20(80)、30(100)A |
|
Frequency |
50Hz |
|
Accuracy |
Class 1.0(active);class 2.0(reactive) |
|
Running with no load |
Yes |
|
Power burden |
Voltage circuit: ≤2w and 5VA,Current circuit:≤2.5VA |
|
Normal operating temp. |
-25℃~+55℃ |
|
Limit operating temp. |
-25℃~+70℃ |
|
RH |
≤85% |
|
RTC accuracy(Day) |
≤0.5s(23℃) |
|
Communication protocol |
DL/T645-1997 |
|
Size |
268mm*171mm*75mm |
|
Weight |
About 1.7Kg |
|
|