Name: Mornitor Management System
Order Info
Description:

Main function
  • Remote :2/4 wheel (tripping sequence)、Remote command has the priority to be operated by the terminal; The terminal can execute the command from main station and sends out the corresponding sound light alarm.
  • Calling up of electric fee alarm: Main station will send out the command of calling up of electric fee to the terminal. After received, the terminal will auto execute the calling-up command with sound (or voice) to inform the user .After the user made the payment, calling-up will be stopped.
  • Remote communication: 4/8 route
  • Impulse: 2/4 route
  • User interface: 1 way (optional, RS485, maximum baud rate 9600bps)
  • Reading interface:1 way (RS485, maximum baud rate 9600bps), the terminal has RS485 interface for meter reading. It can read multi-function meter. The terminal has a few of built-in communication protocols to achieve AMR function with the meters manufactured at home abroad.
  • Real –time data: Active /Reactive impulse power, impulse energy, power factor of every phase and the total ,three phase voltage and current, import/export active /reactive power of every phase and the total ,import/export power factor, of every phase and the total, harmonic data, power grid frequency ,meter status etc.
  • Statistical data: voltage, current, power, energy, demand
  • History data: Day data, month data.
  • Energy supply guarantee: in order to ensure the energy supply for important customers’ load, the terminal can received the command of energy supply guarantee from main power station .At the same time, the terminal will be prohibited to execute any operation.
  • Abnormal measurement detection and anti-tamper: voltage reverse phase sequence detection, current reverse phase sequence detection, PT second short-circuit. CT second open circuit detection, current reverse polarity detection, phase missing detection etc
  • Running events detection: The terminal cam detect the running events at site such as broken phase, power off etc.
  • Broken phase: to detect three phase voltage is broken or not after the terminal is set to active the broken phase function.
  • Power on/off record: The record includes start and stop time for every power off event.
  • Hardware reset: Hardware will be initialized and system variables will be cleared
  • Data area reset: to clear the configure parameters in E2PPPOM except the terminal address ID. It also has the above reset function.
  • Information service: The terminal can receive the information from main station and issue out the alarm .16 pieces of information can be stored in the terminal at most.
  • Events record: The terminal can store 256 pieces of records such as power on/off event, trip record, remote control record, electricity purchase.
  • Sound alarm and alarm display :trip alarm ,switch on alarm, over limit alarm ,parameter setting alarm ,enter/exit of function control, enter/exit of electricity control ,Main station notice ,etc. main station itself can write related message to display on the terminal.
  • Event upload: running events; operation situation events, upload control
  • Software download: The terminal can support system programming (ISP) and on-line programming (IAP)
  • Energy measurement: to measure import/export active/reactive energy with the accuracy CL1.0 and CL0.5.
  • Clock detection and time-comparative